Weld Strength Calculator

Calculate filler metal weld strength per AISC Specification

Select filler metal classification

in

Throat dimension for fillet weld (use 0.707 × leg for actual throat)

in

Results

Design Weld Strength (ϕRn)66.81kips
Effective Throat (aw)0.1767in
Filler Metal Strength70ksi

Calculation Details

ϕRn = 0.75 × (0.60 × 70 × 0.177 × 12) = 66.81 kips

Based on AISC Specification Section J2.4

ϕ = 0.75 for weld metal (LRFD)

Reference: AISC J2-4

The design strength of weld metal, ϕRn, shall be determined using Rn = 0.60 × Fexx × aw × L, where Fexx is the electrode classification stress, aw is the effective throat, and L is the weld length.

Disclaimer: These calculations are for educational and preliminary design purposes only. Always verify results with qualified engineering analysis before use in actual construction.